检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中国计量科学研究院化学计量与分析科学研究所,北京100013
出 处:《现代科学仪器》2009年第3期69-72,共4页Modern Scientific Instruments
摘 要:高精密库仑滴定法是国际上公认的基准测量方法,该方法根据法拉第电解定律,通过质量、电阻、电动势、时间等基本物理量及法拉第常数来进行三氧化二砷纯度的测定,直接溯源到国际SI单位,不需要用标准物质进行比对。样品以氢氧化钾溶液溶解,通过电解产生碘与亚砷酸盐定量反应,以死停终点法确定终点。该方法具有很高的测量精度和准确性。The constant current coulometry as a primary method is recognized in international. Based on Faraday's law of electrolysis, it has been successfully used to determine purity of arsenic trioxide. The measuring results depend directly on the reliability of measuring physical quantities (mass, resister, voltage, time) and fundamental constants expressed in SI units, and do not need a reference material for comparison. The sample dissolved in potassium hydroxide solution. The titration reagent 12 reacted quantificationally with arsenide. The end-point is determined by dead-stop end point. The method is provided with high precise and accurate.