检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]青海省药品检验所,西宁810000
出 处:《药物分析杂志》2009年第7期1169-1171,共3页Chinese Journal of Pharmaceutical Analysis
摘 要:目的:建立高效液相色谱法测定骨刺消痛胶囊中落干酸和龙胆苦苷的含量。方法:采用Elite-ODS色谱柱(4.6mm×250mm,5μm),以乙腈-0.3%乙酸溶液(10∶90)为流动相;流速:1.0mL.min-1;柱温:35℃;检测波长:250nm。结果:落干酸进样量在0.12~0.98μg范围内与峰面积线性关系良好(r=0.9997);龙胆苦苷进样量在0.36~1.46μg范围内与峰面积线性关系良好(r=0.9996)。骨刺消痛胶囊中落干酸和龙胆苦苷的的平均回收率分别为99.2%和99.7%。结论:采用HPLC法测定骨刺消痛胶囊中落干酸和龙胆苦苷的含量,样品处理方法简便,测定结果准确,方法专属性强,精密度高,重复性好,可用于骨刺消痛胶囊的质量控制。Objective:To establish a HPLC method for simultaneous determination of loganic acid and gentiopicroside in GuciXiaotong Capsules. Method: An external standard method with Elite - ODS as fixed phase and acetonitrile -0.3% acetic acid solution (10: 90) as mobile phase was adopted. The column temperature was set at 35 ℃. The wavelength for the detection was 250 nm and the flow rate was 1.0 mL·min^ -1. Results: The linear range of loganic adid was good within the range of 0. 12 -0. 98 μg(r = 0. 9997) and that of gentiopicroside was good within the range of 0.36 - 1.46 μg( r = 0. 9996). The average recoveries of loganic adid and gentiopicroside were 99.2% and 99.7% in GuciXiaotong Capsules. Conclusion: The method is simple, accurate, stable and reliable for the simultaneously determination of loganic adid and gentiopicroside in GuciXiaotong Capsules.
关 键 词:骨刺消痛胶囊 落干酸 龙胆苦苷 HPLC 含量测定
分 类 号:R917[医药卫生—药物分析学]