高效液相色谱-串联质谱测定人血浆中烯丙雌醇  

Determination of allylestrenol in human plasma by liquid chromatography-tandem mass spectrometry

在线阅读下载全文

作  者:吴寅[1] 杭太俊[2] 徐晓峰[2] 陈晓莉[1] 赵培西[1] 金鑫[1] 王靖雯[1] 文爱东[1] 

机构地区:[1]第四军医大学西京医院药剂科,西安710032 [2]中国药科大学药物分析教研室,南京210009

出  处:《中国新药杂志》2009年第12期1121-1124,共4页Chinese Journal of New Drugs

摘  要:目的:建立人血浆中烯丙雌醇的LC-MS/MS浓度测定方法,并评价国产与进口烯丙雌醇片的人体生物等效性。方法:采用Curosil-PFP色谱柱(250 mm×4.6 mm,5μm);柱温25℃;流动相为甲醇-水(95∶5);流速为1.0 mL·min^-1;通过液相串联质谱,大气压化学电离(APCI),以选择反应监测(SRM)方式进行检测。结果:血浆中烯丙雌醇的最低定量限为0.04 ng·mL^-1,在0.04-20.0 ng·mL^-1范围内线性关系良好,批内及批间精密度RSD分别小于1.3%和3.1%。受试制剂与参比制剂的各主要药动学参数:Tmax分别为(1.9±0.5)和(2.0±0.7)h,Cmax分别为(13.63±4.05)和(13.00±3.77)ng·mL^-1,t1/2分别为(9.46±2.88)和(8.77±3.53)h,用梯形法计算AUC0-36 h分别为(46.88±17.48)和(45.16±16.81)ng·h·mL^-1。2种制剂的主要药动学参数Cmax和AUC0-36 h经对数转换后进行方差分析及双单侧t检验,并计算90%置信区间,表明2种制剂生物等效,相对生物利用度为(106.4±29.1)%。结论:该方法简便、灵敏度高,2种烯丙雌醇制剂在人体内生物等效。Objective: To establish a LC-MS/MS method for the determination of allylestrenol in human plasma and to evaluate the bioequivalence of domestic and imported allylestrenol tablets in healthy volunteers. Methods:The samples were separated on a Curosil-PFP (250 mm × 4.6 mm,5 μm) chromatographic column at 25 ℃. The mobile phase consisted of methanol-water (95:5 ) at the flow-rate of 1.0 mL·min^-1 A Finnigan TSQ tandem mass equipped with atmospheric pressure chemical ionization source (APCI) was used as detector and operated in the positive ion mode and selected reaction monitoring ( SRM). Results :The low determination limit of allylestrenol in plasma was 0.04 ng·mL^-1 and a good linearity was obtained over a range of 0.04 -20.0 ng·mL^-1 The intra- and inter-run standard deviations were less than 1.3% and 3.1% , respectively. The pharmacokinetie parameters of the test and reference preparations were as follows : Tmax ( 1.9 ± 0.5 ) and (2.0 ± 0.7 ) h, Cmax ( 13.63 ± 4.05) and (13.00±3.77) ng·mL^-1,t1/2(9.46±2.88) and (8.77 ±3.53) h,and AUC0-36h(46.88 ±17.48) and (45.16 ± 16.81 ) ng·h·mL^-1 , respectively. The relative bioavailability of the test product to the reference was (106.4 ± 29.1 )%. Conclusion:This method is simple,sensitive and suitable for clinical pharmacokinetics or bioequivalence studies. The two allylestrenol formulations were bioequivalent.

关 键 词:烯丙雌醇 高效液相色谱-串连质谱 药动学 生物等效性 

分 类 号:R969.1[医药卫生—药理学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象