检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:黄爱忠[1] 童玉珍[1] 胡鹏程[1] 徐永军[1]
机构地区:[1]中国石化金陵分公司烷基苯厂,江苏南京210046
出 处:《化工时刊》2009年第7期32-33,共2页Chemical Industry Times
摘 要:通过酸化-吹气-吸收装置来提取液体石油产品中的硫化氢,在酸性条件下,硫化物与过量的碘作用,剩余的碘用硫代硫酸钠滴定,由硫代硫酸钠溶液所消耗的量,间接求出硫化氢的含量。经过一系列实验发现:该分析方法加标回收率在94.48%~97.36%,标准偏差0.0159,变异系数2.05%,分析结果表明数据的准确度和精密度较好,取得了满意的效果。The sulfureted hydrogen was extracted from the petroleum products by means of Acidification - Nitro- gen blowing -Absorption Unit. In acidic condition, the sulfured reacted with excessive iodine. The surplus iodine was titrated with sodium thiosulfate. Based on the amount of sodium thiosulfate consumed, the sulfureted hydrogen content was calculated indirectly. After a series of experiments, it was found that the recovery was 94.48 - 97.36%, the standard deviation was 0.015 9 and coefficient of variation was 2.05% using this analysis method. The analysis data were accurate and precise.
关 键 词:酸化-吹气-吸收装置 碘量法 硫化氢 硫代硫酸钠
分 类 号:TE622.1[石油与天然气工程—油气加工工程]