Fenton氧化-混凝联合处理橡胶废水研究  被引量:13

STUDY ON RUBBER WASTEWATER TREATMENT BY FENTON OXIDATION UNITED WITH COAGULATION

在线阅读下载全文

作  者:闫肖茹[1] 高建平[1] 王建中[1] 杨建涛[1] 李慧[1] 

机构地区:[1]西北师范大学地理与环境科学学院,甘肃兰州730070

出  处:《水处理技术》2009年第8期99-102,共4页Technology of Water Treatment

摘  要:以橡胶厂的工业废水为研究对象,探讨了各种因素对Fenton氧化后废水混凝处理效果的影响,并对H2O2、FeSO4·7H2O和Fe2(SO4)3用量进行L9(33)正交试验,确定Fenton氧化-混凝联合工艺处理橡胶废水的最佳反应条件为:质量分数30%的H2O2、FeSO4·7H2O和Fe2(SO4)3投加量分别为2mL、0.3g和0.3g。与Fenton氧化法和直接混凝法相比,Fenton氧化-混凝联合工艺对橡胶废水处理效果更好,对COD去除率明显高于单独采用2种方法对COD去除率的总和。With rubber wastewater as the object of study, H2O2 dosage, coagulation solution pH value, coagulation dosage and reaction time which had notable effect on the coagulation process with Fenton preoxidation water were investigated. According to L9(3^3) orthogonal experiments with H2O2(30%) dosage, FeSO4·7H2O dosage and Fe2(SO4)3 dosage, the optimal dosage were 2 mL, 0.3 g and 0.3 g respectively. The united process had better COD treatment result than that of Fenton oxidation or direct coagulation.

关 键 词:FENTON氧化 混凝 橡胶废水 COD去除率 

分 类 号:X783.3[环境科学与工程—环境工程]

 