复合式土壤源热泵地埋管换热器性能影响因素  被引量:5

Factors Influencing Performance of Buried Tube Heat Exchanger of Hybrid Ground Source Heat Pump

在线阅读下载全文

作  者:郭卉[1] 陈祖铭[2] 陈超核[3] 丁力行[1] 

机构地区:[1]仲恺农业工程学院,广东广州510225 [2]华南理工大学建筑设计研究院,广东广州510640 [3]海南大学,海南海口570228

出  处:《煤气与热力》2009年第8期5-8,共4页Gas & Heat

基  金:国家自然科学基金(50868004);广东省科技计划(2007B080701002);海口市重点科技计划(20080000180);海南省自然科学基金项目(50654);云浮-仲恺科研基金(G2004002)

摘  要:以配置冷却塔的复合式土壤源热泵为研究对象,建立了地埋管换热器简化计算模型。分析了地埋管换热器管内水流量、进水温度、土壤初始温度、地埋管连接形式对其性能的影响。探讨了地埋管换热器与冷却塔的联合工作特性。Taking the hybrid ground source heat pump with cooling tower as research object, a simplified calculation model of buried tube heat exchanger is established. The influence of water flow in buried tube heat exchanger, inlet temperature, initial soil temperature and connection mode of buried tubes on its performance is analyzed. The conjoint operation characteristics of buried tube heat exchanger and cooling tower are discussed.

关 键 词:复合式地源热泵 地埋管换热器 性能 冷却塔 