青霉素废水厌氧毒性试验研究  被引量:3

Research on the toxicity tests for treating penicillin wastewater by anaerobic digestion

在线阅读下载全文

作  者:胡晓东[1] 梁晓媚[1] 樊建军[1] 李润祺[1] 郑秋辉[1] 

机构地区:[1]广州大学土木工程学院,广东广州510006

出  处:《工业水处理》2009年第8期52-55,共4页Industrial Water Treatment

摘  要:采用单体试验、重复试验、相互作用试验考察青霉素废水厌氧消化过程中的抑制性物质及其浓度对处理效果的影响。研究表明,青霉素废水厌氧消化的抑制性物质主要是破乳剂1231和SO42-。采用厌氧生物法处理青霉素废水时,需将破乳剂1231的进水质量浓度控制在<200mg/L,将SO42-的进水质量浓度控制在<1000mg/L。By means of monomer test, repetition test and relative action test, the effect of the suppressive substances in the anaerobic digestion process of penicillin wastewater and its concentration on the treatment efficiency has been investigated. The research indicates that the suppressive substances in the anaerobic digestion process of penicillin wastewater are mainly de-emulsifier 1231 and SO4^2-. When anaerobic biological method is used for treating penicillin wastewater, the influent water mass concentration of de-emulsifier 1231 and SO4^2- should be less than 200 mg/L and 1 000 mg/L, respectively.

关 键 词:青霉素废水 厌氧消化 抑制性物质 

分 类 号:X703.1[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题