检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]浙江省医学科学院药物研究所,杭州310013
出 处:《华西药学杂志》1998年第3期156-158,共3页West China Journal of Pharmaceutical Sciences
摘 要:采用反相高效液相色谱法测定雌二醇透皮控释制剂的含量和溶出度。色谱柱SperisorbC18(4.6×250mm);流动相:甲醇-水(75:25);检测波长:280nm。溶出度用浆法测定,转速30rpm/min;溶出介质:1%聚乙二醇-400。线性范围:5.0~80.0μg/ml(n=5,r=0.996),雌二醇最低检出量为5ng,平均回收率:99.27%,(RSD=0.3%),日内和日间RSD分别为1.93%(n=5)和2.45%(n=5),168h的累积溶出度大于80%,不同批号E2-TDS溶出度测定重现性良好。方法操作简便,快速,准确,为透皮制剂的质量控制提供了新的分析方法。Determination of estradiol in estradiol transdermal delivery system E2-TDS and its dissolution by RP-HPLC. Sperisorb C18 column (4. 6×250mm, 5μm), mobile phase: CH3OH-H2O (75: 25 ),UV detection at 280nm,a paddle method was used to study the dissolution, the rotative relocity was 30rpm/min and the solvent was 100ml of 1% PEG400. The linear range of standard curve was 5.0-80.0 μg/ml, r=0.996 (n=5). The average recovery of assay was 99.27% with a relative standard deviation of 0. 43% (n=3), the preciscin within-day RSD was 1. 93% (n=5 ), the dissolution profiles were found to be virtully superimposible for different batches of E2TDS. The accumlative release rate over 80% in 168h,the dissolution protiles were found to be virtually superimposalle for different fatch of E2-TDS.