培养法与Equate^(TM)抗原检测法检测集中空调冷却水军团菌  被引量:2

Detection of Legionella in water of cooling tower by culture and Equate^(TM) antigen detection assay

在线阅读下载全文

作  者:张琦[1] 陈晓东[1,2] 张宝莹[3] 张秀珍[2] 杜雪飞[4] 曾晓燕[2] 陈连生[2] 

机构地区:[1]南京医科大学公共卫生学院,南京210029 [2]江苏省疾病预防控制中心,南京210009 [3]中国疾病预防控制中心,北京100050 [4]南京市疾病预防控制中心,南京210002

出  处:《中国卫生检验杂志》2009年第8期1820-1822,共3页Chinese Journal of Health Laboratory Technology

基  金:"十一五"国家科技支撑计划项目(2006BAI19B04)

摘  要:目的:了解集中空调冷却水军团菌污染状况和血清型分布,评价利用EquateTM水军团菌快速试验试剂盒检测军团菌。方法:选取南京、常州、苏州共148家集中空调冷却塔,每个冷却塔平行采集两份水样,分别用培养法和EquateTM水军团菌快速试验试剂盒检测军团菌。结果:培养法军团菌的总阳性率为75%,共检出菌株145株,血清型分布以LP1(65.5%)为主,LP2-8、L.micdadei、L.bozemanii均有检出;EquateTM试剂盒检测LP1阳性率为57.4%,与培养法比较差异无统计学意义(McNemarχ2=1.56、P=0.26),检测灵敏度、特异度易受其他细菌干扰。结论:集中空调冷却水军团菌污染较普遍,血清型别多样以LP1为主。EquateTM水军团菌快速试验试剂盒,可作为培养法的辅助手段用于突发事件应急,筛查高浓度LP1污染,不适于常规监测。Objective: To learn the pollute status and its serum type of Legionella in the cooling tower water of central air-conditioning and evaluate the utility of the Equate^TM water Legionglla test kit for detection of Legionella.Methods:From Nanjing,Changzhuo,Suzhuo 148 cooling towers water of central air-conditioning were recruited and measured the prevalence of Legionella by culture and the Equate^TM water Legionglla test kit.Results:The positive detective rate of culture was 75%,and 145 strains were isolated.The distribution of serum of Legionella mostly was LP1(65.5%),others were LP2-8,L.micdadei,L.bozemanii;The positive rate of LP1 by the Equate^TM test kit was 57.4%.To compare with culture,the distinction has not statistics significance(McNema χ^2=1.56,P=0.26).But the sensitivity and specificity of detection was interference by other bacteria.Conclusion:The pollution status of Legionella in central air conditioning cooling water was common,and its serotypes is manifold,the most serotype was LP1.The Equate^TM test kit could be considered as an adjunct to culture for emergency,screening of high concentration of pollution LP1,but not suitable for water environment regular monitoring of Legionella.

关 键 词:军团菌 集中空调 冷却塔水 检测 

分 类 号:R446.5[医药卫生—诊断学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象