水中铅的自动快速测定  被引量:3

Automatic and Rapid Analysis of Microamounts of Lead in Industrial Waste Water

在线阅读下载全文

作  者:徐宏亮[1] 廖琴仙[1] 徐金华[1] 

机构地区:[1]中南工业大学化学系

出  处:《冶金分析》1998年第4期6-8,共3页Metallurgical Analysis

基  金:湖南省科委重点资助项目

摘  要:自行研制和组装了自动光度分析仪,结合流动注射分析(FIA)—光度法,对水中微量铅进行测定。在90s内完成一个试样的全自动分析。采样频率为40个样/h,铅在0~4.0μg/ml浓度范围内符合比尔下律。该法对株州治炼厂的总排净化水和铅系统的生活废水进行了测定,结果令人满意。Based on the flow injection-spectrophotometry,an automatic photometric analyzer is designed to determine the microamount lead in industrial waste water.The analysis process including zeroing,sample loading and injecting,data reading,standard calibration,measurment of absorbance and results printing can be completed in 90s and Beer’s law is obeyed in range of 0-4.0μg/ml.The sampling frequency is 40 samples/hour.The proposed method has been aplied to the determination of lead in the waste water at Zhuzhou Smelter.The results are satisfactory.

关 键 词: 流动注射分析 自动分析 环境监测 环境水样 

分 类 号:X832.02[环境科学与工程—环境工程]

 