摘 要:研究了新的双噻唑偶氮试剂2,6-二偶氮[4,4'-(双间苯二胺)]-苯骈[1,2-d:4,5-d']二噻唑(BDTADAB)与钯的显色反应.在5.8mol/L硫酸介质中,钯与试剂生成的络合物最大吸收波长为604nm,表观摩尔吸收系数为4.2×104L·mol-1·cm-1,钯在0~16μg/25mL范围内符合比尔定律.常见金属离子及铂、金等贵金属离子均不干扰钯的测定.该方法具有简便、快速、选择性高的特点,可用于实际样品中微量钯的测定.The colour reaction of Palladium with 2,6 bisazo [4,4' (bis m phenylendiamine)] benzo[1,2 d: 4,5 d']bisthazole has been studied. In a solution of 5.8 mol/L H 2SO 4,Pd forms a stable complex with BDTADAB showing maximum absorption at 604 nm with a molar absorptivity 4.2×10 4 L·mol -1 ·cm -1 . Beer's law is obeyed in the range of 6~16 μg/25mL for Pd(II).The common metal ions and the precious metal ions such as Pt 4+ 、Au 3+ don't interfere. The method has been applied to the determination of Pd(II) in samples with satisfactory results.