D210塔筒体泄漏原因分析  

Leakage Reason Analysis in Cylinder of Tower D210

在线阅读下载全文

作  者:钱耀洲[1] 游菊[1] 

机构地区:[1]上海市特种设备监督检验技术研究院,上海200062

出  处:《理化检验(物理分册)》2009年第9期570-572,共3页Physical Testing and Chemical Analysis(Part A:Physical Testing)

摘  要:采用化学成分分析、金相检验和断口分析等方法,对304L钢D210塔筒体泄漏原因进行了分析。结果表明:D210塔筒体泄漏原因是由于氯离子的存在而产生应力腐蚀开裂所致。由于敏感材料、应力腐蚀环境及应力三个条件共同存在,在一定温度下使其产生应力腐蚀裂纹,裂纹起始于筒体外壁角焊缝处,而后向内壁扩展,最终穿透筒壁,致使该塔筒体在角焊缝处产生破裂泄漏。The leakage reason in cylinder of the tower D210 was analyzed by chemical composition analysis, metallographic examination and fracture analysis. The analysis result showed that the leakage was caused by stress corrosion cracking which resulted from existing chloride ion. Under the certain temperature, stress corrosion crack produced at the combined effect conditions of sensitive materials, stress corrosion circumstance and tensile stress. The crack, which initiating in fillet weld on outer cylinder, extended to the wall and eventually penetrated the tube wall Then towers cylinder leaked on the fillet weld.

关 键 词:筒体 应力腐蚀开裂 氯离子 泄漏 

分 类 号:TQ053.5[化学工程]

 