转化炉下集气管导淋管破裂原因分析及处理措施  

Analysis on causes for fracturing of drain tubes of the lower manifold of converter and treatment measures

在线阅读下载全文

作  者:高珊珊[1] 鲁敏[2] 姜雪枫[3] 

机构地区:[1]大庆石化公司经济技术开发公司,黑龙江大庆163714 [2]大庆石化公司化工三厂,黑龙江大庆163714 [3]大庆石化公司生产运行处,黑龙江大庆163714

出  处:《炼油与化工》2009年第3期25-27,共3页Refining And Chemical Industry

摘  要:用光学显微镜、扫描电镜对转化炉下集气管的导淋管的微观组织、断口形貌进行分析。结果表明:导淋管鼓胀破裂非蠕变损伤所致,而是超温运行所致,超温是导淋管阀门泄漏引起的。应用HP50Nb高性能材质后使问题得以解决。The optical microscope and scanning electron microscope were used to analyze the microstructure and fracture mode of the bulging-fractured drain tubes of the lower manifold of the converter. The result shows, the bulging fracture of the drain tubes was caused by over-temperature operation, not by creep damage, and the over temperature was caused by the leakage of drain tube valves. The problem can be solved by using high performance material HP50Nb.

关 键 词:转化炉 导淋管 破裂 处理措施 

分 类 号:TQ113[化学工程—无机化工]

 