检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李国强[1] 张建岗[1] 赵兵[1] 马安平[1] 王学新[1]
出 处:《辐射防护》2009年第5期352-355,共4页Radiation Protection
摘 要:FCo70-YQ型放射源运输容器是设计用于运输60Co和137Cs的医用放射源运输容器,设计容器最高装源活度60Co不超过12000C(i444TBq),137Cs不超过8000C(i296TBq)。根据国家标准《放射性物质安全运输规程》(GB 11806ˉ2004)的要求,对FCo70ˉYQ型容器进行了耐热试验。试验中测量到容器本体的最高温度为193.9℃,小于容器屏蔽材料铅的熔点温度327.3℃。试验结果证明了FCo70-YQ型容器热工设计满足国家标准《放射性物质安全运输规程》(GB 11806-2004)的要求。The FCo70-YQ-Type container is intended for transport of medical ^60Co and 137Cs sealed sources. The activity of ^60Co is less than 12 000 Ci (444 TBq), and the activity of ^137Cs is less than 8 000 Ci (296 TBq). FCo70-YQ Type container experienced thermal test in accordance with safety requirements of Regulations for the Safe Transpor t of Radioactive Mater ial (GB 11806-2004). The measured maximum temperature on main body of container is 193.9℃ during testing period, which is less than the melting point of lead (327.3℃). The results obtained proven that thermal design of FCo70-YQ container meets the requirements of Regulations for the Safe Transport of Radioactive M aterial(GB 11806-2004).
关 键 词:耐热试验 FCo70-YQ型容器 运输 放射源
分 类 号:TL932[核科学技术—辐射防护及环境保护]