检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘静[1] 钱林茂[1] 董汉山[2] Joseph Buhagia
机构地区:[1]西南交通大学牵引动力国家重点实验室摩擦学研究所,四川成都610031 [2]英国伯明翰大学冶金与材料学院,B152TT
出 处:《摩擦学学报》2009年第5期399-404,共6页Tribology
基 金:国家自然科学基金资助项目(90923017,50625515,50821063)
摘 要:采用液压伺服微动试验机,在模拟体液中试验研究了430℃渗氮、430℃氮碳共渗与500℃渗碳等3种表面改性工艺对医用奥氏体不锈钢316LVM微动腐蚀磨损性能的影响.结果表明,3种工艺均可在奥氏体不锈钢表面形成扩展奥氏体相"S相",明显地提高基体硬度和弹性模量,进而改善其微动腐蚀磨损性能.在本文试验条件下,430℃氮碳共渗样品的耐微动腐蚀磨损性能最好,是医用奥氏体不锈钢316LVM抗微动磨损性能最优的表面改性工艺.The effect of the surface treatment on the fretting wear behavior of 316LVM austenitic stainless steel was investigated in the Ringer's solution by a Servo Hydraulic Dynamic Test machine. Three kinds of surface treatments were used in the experiments, namely low - temperature plasma nitriding at 430℃, carbonitriding at 430℃, and carburising at 500 ℃, respectively. The experimental results indicated that all the three treatments created a layer of "S" phase on the sample surface, which effectively improved the hardness and elastic modulus of 316LVM and further enhanced its anti -corrosion and anti -wear properties. The 316LVM nitrided at 430℃ showed the similar friction behavior as that carbonitrided at 430℃. Even the 316LVM carburised at 500 ℃ exhibited the lowest friction coefficient; the low - temperature plasma carbonitrided at 430℃ was the best surface treatment of three against the fretting wear of medical grade 316LVM austenitic stainless steels in this experiment.
分 类 号:TH117.3[机械工程—机械设计及理论]