检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]南京工业大学城市建设与安全工程学院,江苏省城市与工业安全重点实验室,江苏南京210009
出 处:《化工学报》2009年第10期2490-2496,共7页CIESC Journal
基 金:“十一五”国家科技支撑计划重点项目(2007BAK22B04-9);国家自然科学基金项目(29936110)~~
摘 要:寻找安全有效的反应条件一直是绿色化工的重要研究内容之一。采用邻二甲苯氧化的反应动力学模型,分析了非绝热式固定床反应器的参数灵敏性和热失控行为,考察了非绝热式固定床反应器温度对冷却介质流量、进料温度和初始压力的敏感性。模拟计算结果表明,当反应进入敏感性区域后,反应器对冷却介质流量、进料温度和初始压力的改变极其敏感。采用系统散度判据(div>0)计算该反应的热失控临界操作参数,计算结果与文献中的判据进行了分析比较,得到类似的结果,但计算更简单。考虑冷却介质的影响,修正了div判据,得到更准确的热失控临界操作参数。研究结果表明,此判据能为反应器的设计及过程控制提供重要的参考依据。Safe and effective reaction condition is one of the important issues in green chemical technology. Parametric sensitivity and thermal runaway behavior in non-adiabatic fixed bed reactors were analyzed by using a reaction kinetics model for ortho-xylene oxidation. The sensitivity of thermal behavior in a non-adiabatic fixed bed reactor was also examined with respect to cooling medium flow rate, feeding temperature and initial pressure. The simulation results showed that the non-adiabatic fixed bed reactor became extremely sensitive to small changes in cooling medium flow rate, feeding temperature and initial pressure when the reactor was operated in the sensitivity region of parameter space. The divergence (div) of the system was used to calculate the critical operating parameters and similar results were obtained in comparison with the criteria of literature. However, the divergence method was simpler than the existing criteria. Finally, the influence of cooling medium was taken into consideration to modify the div criterion, and more exact thermal runaway critical operating parameters were obtained. This criterion could provide good reference for reactor design and process control.
关 键 词:参数敏感性 热失控 非绝热式固定床反应器 临界操作参数
分 类 号:TQ086.3[化学工程] X937[环境科学与工程—安全科学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.169