湿法脱硫系统设计无旁路相关问题的探讨  被引量:4

DISCUSSION ON INVOLVED ISSUES OF WET DESULFURATION SYSTEM WITHOUT BYPASS DESIGN

在线阅读下载全文

作  者:李庆[1] 毛永清[1] 陈志良 黄杰 

机构地区:[1]华北电力科学研究院有限责任公司,北京100045 [2]国华三河发电厂,河北燕郊065201

出  处:《环境工程》2009年第5期84-87,98,共5页Environmental Engineering

摘  要:介绍国内电厂首次投运的无旁路脱硫系统,其具有无GGH、引风机和增压风机合并、"烟塔合一"的特点。通过与其他脱硫系统的比较,讨论了无旁路脱硫系统吸收塔、烟道、公用系统以及除尘器的设计和选型特点,总结了其易出现的问题及运行中的控制方法。根据调试经验,给出了无脱硫旁路系统的运行步序原则。The desulfuration system, which is introduced as the first one without bypass design in domestic power plants, has the characteristics of no GGH design, integrating induced draft fan with booster fan and integrating chimney with cooling tower. The design and choices of absorber tower, duct, common system and dust collector are discussed and compared with other desulfuration systems. The possible issues during running are analyzed and the relative solutions are provided. According to the commissioning experiences, the running steps are suggested for the desulfuration system without bypass design.

关 键 词:脱硫系统 无旁路设计 烟塔合一 

分 类 号:X701.3[环境科学与工程—环境工程]

 