作 者:向瑾[1] 曹伟[1] 熊应兴 黄翔[3] 张益谦[4]
机构地区:[1]四联智能技术股份有限公司,西安710075 [2]陕西工程勘察研究院,西安710068 [3]西安工程大学,西安710048 [4]长安大学,西安710064
出 处:《建筑科学》2009年第10期53-56,69,共5页Building Science
摘 要:水源热泵作为一种节能环保的供热制冷技术,正在受到越来越多的关注。本文分析了杨凌五湖路地区的气象与地质地貌情况,通过对该地区5口试验井的抽水、回灌试验分析及水质分析,指出该区域非常适合水源热泵系统的应用与推广,当设计单井抽水量在80~1003/h时,抽水与回灌井的比例宜按1:2设置。As an energy-saving and environmental protection technology, water-source heat pump system attracted more and more concerns. In this paper, the meteorological and geological features of the area of Yangling Wuhu Road were analyzed, as well as the water quality. And then, with the experimental analysis on pumping and recharging of five wells,it was pointed out that this region was ideal for the application and promotion of water-source heat pump system. In addition, it was known that when the single well pumping at a range from 80 to 100 m^3/h,the well ratio of pumping and recharging should be 1:2.