检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:关维民[1]
出 处:《海军总医院学报》2009年第3期155-157,共3页Journal of Naval General Hospital of PLA
摘 要:目的观察去管化乙状结肠储尿囊可控性尿流改道术(改良MainzⅡ式)临床效果。方法5例膀胱癌患者,膀胱全切术后采用改良MainzⅡ式,分析围手术期情况、术后控尿情况、贮尿囊容积、影像学检查情况、实验室检查情况、术后并发症。结果手术时间4.3~5.5 h,术中出血量300~545 ml,术后下床时间6~9 d,留置单J管时间8~13 d,留置尿管时间19~22 d,全部患者白天及夜间控尿良好。结论改良MainzⅡ式膀胱术操作简单,效果良好,能保证肠管的连续性和尿液可控性,并发症少,患者生存质量提高。Objective To investigate the clinical outcome of diversion using detubularized sigmoid colon as urinary reservoirs. Methods We selected 5 patients with muscle-invading bladder carcinoma who underwent a Mainz pouchⅡ procedure after radical cystectomy. Peri-operative situation, postoperative continence, the mean volume of pouch, imaging, laboratory and post-operative complications were analyzed. Results Operation time, bleeding, single J catheter time and indwelling catheter time were 4.3--5.5 h,300--545 ml,8.0--13.0 d and 19.0--22.0 d respectively.Conclusion Modified MainzⅡ method is simple and safe,it is also a better alternative diver sion procedure easily accepted by surgeons and patients.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.191.254.28