检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]新疆电力设计院,新疆乌鲁木齐830002 [2]东北电力大学,吉林吉林132012
出 处:《四川电力技术》2009年第5期71-74,82,共5页Sichuan Electric Power Technology
摘 要:提出了一种基于实测的功角曲线检测区域间低频振荡模式的新方法,这种方法能有效检测出互联系统的区域间主导低频振荡模式,因此可以对扰动下的系统进行有效的分析。大系统算例结果表明,所提方法能准确的检测识别出系统主导区域间低频振荡模式,其结果与综合稳定程序(PSASP)计算出的结果一致,从而验证了所提新方法的正确性和有效性。Based on the measured power angle curve, a new method of detecting inter - regional low - frequency oscillation (LFO) mode is presented, it can effectively detect inter - regional LFO mode, so the power system with disturbance can be effectively analyzed. The results of large power grids show that the proposed method can accurately identify the dominant mode of inter - regional LFO, they are the same as the resuh that is calculated by PSASP, thereby the proposed method proved to he correct and effective.
分 类 号:TM712[电气工程—电力系统及自动化]