Diagnostic performance of magnetic resonance venography in the detection of recanalization in patients with chronic cerebral venous sinus thrombus  被引量:7

Diagnostic performance of magnetic resonance venography in the detection of recanalization in patients with chronic cerebral venous sinus thrombus

在线阅读下载全文

作  者:SUN Ying ZHENG Dong-you JI Xun-ming Peter WEALE WU Hao JIANG Li-dan YANG Li-zhuang 

机构地区:[1]Department of Neurosurgery, The 2nd Affiliated Hospital of Harbin Medical University, Harbin 150086, China [2]Department of Anesthesiology, Beijing Tiantan Hospital, Capital Medical University, Beijing 100050, China [3]Department of Neurosurgery , Xuanwu Hospital, Capital Medical University, Beijing 100053, China [4]Department of Radiology , Xuanwu Hospital, Capital Medical University, Beijing 100053, China [5]Siemens Medical Solutions USA, Inc., Chicago, IL 60611, USA

出  处:《Chinese Medical Journal》2009年第20期2428-2432,共5页中华医学杂志(英文版)

摘  要:Background In the chronic stage of cerebral venous sinus thrombosis (CVST), recanalization can result in disparate MR appearances. We aimed to prospectively investigate the diagnostic accuracy of magnetic resonance venography (MRV) in the evaluation of the recanalization of CVST. Methods This study prospectively evaluated the diagnostic performance of 2-dimensional time-of-flight (2D-TOF) MRV in thirty-two consecutive patients during a threeto six-month follow-up for CVST. Both 2D-TOF MRV and digital substraction angiography (DSA) were undertaken. Diagnostic accuracy of 2D-TOF MRV in the detection of recanalized thrombus was evaluated using DSA as the reference standard. Results MRV and DSA were completed without complications in all 32 patients. The sensitivity, specificity, positive predictive value, and negative predictive value of 2D-TOF MRV for the detection of recanalization on a segmental basis were 91% (62/68), 93% (37/40), 95% (62/65), and 86% (37/43) respectively. Conclusion 2D-TOF MRV provides high sensitivity and specificity for the diagnosis of recanalized CVST segments.Background In the chronic stage of cerebral venous sinus thrombosis (CVST), recanalization can result in disparate MR appearances. We aimed to prospectively investigate the diagnostic accuracy of magnetic resonance venography (MRV) in the evaluation of the recanalization of CVST. Methods This study prospectively evaluated the diagnostic performance of 2-dimensional time-of-flight (2D-TOF) MRV in thirty-two consecutive patients during a threeto six-month follow-up for CVST. Both 2D-TOF MRV and digital substraction angiography (DSA) were undertaken. Diagnostic accuracy of 2D-TOF MRV in the detection of recanalized thrombus was evaluated using DSA as the reference standard. Results MRV and DSA were completed without complications in all 32 patients. The sensitivity, specificity, positive predictive value, and negative predictive value of 2D-TOF MRV for the detection of recanalization on a segmental basis were 91% (62/68), 93% (37/40), 95% (62/65), and 86% (37/43) respectively. Conclusion 2D-TOF MRV provides high sensitivity and specificity for the diagnosis of recanalized CVST segments.

关 键 词:venous sinus thrombosis  cranial magnetic resonance venography angiography  digital subtraction 

分 类 号:R686[医药卫生—骨科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象