检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Quan Li Longpo Zheng Zhiyu Zhang Zhengdong Cai
机构地区:[1]Department of Orthopedics, Changhai Hospital, Second Military Medical University, Shanghai 200433, China [2]Department of Orthopedics, The Forth Affiliated Hospital of China Medical Nuiversity, Shenyang 110032, China [3]Department of Orthopedics, Shanghai Tenth People's Hospital, Shanghai 200072, China
出 处:《The Chinese-German Journal of Clinical Oncology》2009年第11期638-641,共4页中德临床肿瘤学杂志(英文版)
摘 要:Objective: The aim of this study was to investigate the biomechanical property of lumbosacral reconstruction after subtotal sacrectomy. Methods: Three three-dimensional finite element models of lumbosacral region were established: (1) An intact model (INT); (2) A defective model (DEF) on which subtotal sacrectomy was performed cephalad to the $1 foramina; (3) A reconstructed model (REC). These models were validated by compared with literature. Upright posture was stimulated under a compression load of 925N. A finite element analysis was performed to account for the displacement and stress on the models. The REC model was calculated twice, with the material property of reconstruction instrument set as titanium and stainless steel, respectively. Results: The displacements of anchor point on the L3 vertebrae in INT, DEF and REC model were 6.63 mm, 10.62 mm, 4.29 mm (titanium) and 3.86 mm (stainless steel), respectively. The stress distribution of the instrument in REC model showed excessively concentration on caudal spinal rod, which may cause rod failure between spine and ilia. The maximum von Mise stress of stainless steel instrument was higher than that of titanium instruments (992 MPa vs 655 MPa), and the value of stress of anchor point around sacroiliac joint in REC model were 26.4 MPa with titanium instruments and 23.9 MPa with stainless steel instruments. Conclusion: Lumbosacral reconstruction can significantly increase the stiffness of spino-pelvis of the patient who underwent subtotal sacrectomy. However, the rod between L5 and ilia is the weakest region of all the instruments. It is suggested that the bending of rod should be conducted carefully and smoothly to avoid significant stress concentration so as to reduce the risk of rod failure. And stainless steel instrument has higher maximum stress and significantly greater stress shielding effect than titanium instrument, which means stainless steel instruments are of higher risk of rod failure and less favorable
关 键 词:subtotal sacrectomy RECONSTRUCTION BIOMECHANICS finite element analysis
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.13