检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:姜莉[1] 胡晓静[1] 卢琪[1] 曾泽[1] 牟明仁[1] 高伟[1]
出 处:《理化检验(化学分册)》2009年第11期1331-1333,共3页Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
基 金:国家质检总局科研项目(IK055-2004)
摘 要:矿物饲料样品磷酸钙经硝酸溶解,采用原子荧光光谱法测定其中砷和汞的含量。对影响测定的因素如仪器工作条件、溶样试剂的种类、盐酸介质的浓度、预还原剂的种类、硼氢化钾浓度、共存离子的干扰等作了研究并予以优化。荧光强度与砷和汞的质量浓度分别在100.0,5.0μg·L^(-1)范围以内呈线性关系,检出限(3s)依次为0.18,0.06μg·L^(-1),相对标准偏差(n=11)均小于8.0%。应用此法分析3个矿物饲料,并用标准加入法测得砷和汞的回收率分别为91.7%~103.0%和91.0%~93.7%。The sample of mineral fetted, calcium orthophosphate, was dissolved with HNO3 solution, and the contents of As and Hg in the sample solution were determined by AFS. Influential factors, including working conditions of instrument, kinds of reagents for dissolving sample, concentration of HCl medium, amount of prereductant required, concentration of potassium borohydride, and interferences of coexisting ions, were studied and optimized. Linear relationships between the values of fluorescence intensity and mass concentration of As and Hg found were in the ranges within 100. 0 and 5. 0 μg·L^-1 , with detection limits (3s) of 0. i8 and 0. 06 μg·L^-1, respectively. The values of RSD's (n=11) found were all less than 8. 0%. The proposed method was applied to the analysis of 3 samples of calcium orthophosphate, and test for recovery was made by standard addition method, giving values of recovery in ranges of 91.7%-103.0% (As) and 91.0%--93.7% (Hg).
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.170