热电联供系统中烟气冷凝传热性能试验研究  被引量:3

Experimental Study of the Condensation Heat Transfer Performance of Flue Gases in a Heating-and-power Cogeneration System

在线阅读下载全文

作  者:赵玺灵[1] 付林[1] 张世钢[1] 杨巍巍[1] 

机构地区:[1]清华大学建筑技术科学系,北京100084

出  处:《热能动力工程》2009年第6期756-758,共3页Journal of Engineering for Thermal Energy and Power

基  金:国家863高技术基金资助项目(2006AA05Z252);中国博士后科学基金资助项目(20080430432)

摘  要:针对烟气余热不能充分回收的问题,对能够充分回收烟气余热的新型热电联供系统中的烟气冷凝热回收设备进行试验研究,重点研究该工况下光滑管烟气冷凝设备的传热性能。研究结果表明,在该试验工况下,干式、冷凝段传热系数可达60 W/(m^2.K),冷凝段传热系数为90-100 W/(m2.K),冷凝段传热系数约为干式段传热系数的1.5-1.7倍,并整理了该工况下的传热准则关系式,为该系统型式的推广应用提供设计与运行依据。Concerning the problem of the inability to fully recover the waste heat in flue gases,experimentally studied was a flue gas condensation heat recovery device of an innovative heating-and-power cogeneration system that could fully recover the waste heat in flue gases.In this connection,the research emphasis was laid on the heat transfer performance of a smooth tube flue-gas condensing equipment item under the relevant operating condition.The research results indicate that under the test operating condition,the heat transfer coefficient of the dry type condensing section can be as high as 60 W/(m2·K) with that of the condensing section being 90 to 100 W/(m2·K).The heat transfer coefficient of the condensing section is about 1.5 to 1.7 times that of the dry type one.The authors have also worked out a heat transfer criterion-based relational expression under the operating condition,thus providing an underlying basis for popularizing the design and operation of the system in question.

关 键 词:热电联供 烟气 冷凝热 潜热 传热性能 

分 类 号:TK124[动力工程及工程热物理—工程热物理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象