检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:齐杰[1] 陈倩云[1] 韩江[1] 张婷菊[1] 程实[1] 董全[1] 马蕊[1] 刘贵建[1]
机构地区:[1]中国中医科学院广安门医院检验科,北京100053
出 处:《中国中西医结合肾病杂志》2009年第11期984-987,共4页Chinese Journal of Integrated Traditional and Western Nephrology
摘 要:目的:评价UF-1000i流式尿有形成分分析仪、尿干化学分析仪及相差显微镜联合应用在血尿来源鉴别中的应用价值。方法:选取33例肾小球性血尿、23例非肾小球性血尿,分别用UF-1000i流式尿有形成分分析仪检测尿红细胞数量、尿70%红细胞前向散射光强度(RBC-P70Fsc)、尿红细胞前向散射光分布宽度(RBC-Fsc-DW);用URISYS2400尿干化学分析仪检测蛋白(PRO);用相差显微镜检测尿红细胞数量、畸形红细胞比率。结果:对于血尿来源的鉴别,UF-1000i检查的敏感度100%,特异度82.6%,相差显微镜检查的敏感度93.9%,特异度91.3%。UF-1000i诊断肾小球性血尿的敏感度、特异度ROC曲线下面积为0.966(P<0.01),相差显微镜诊断肾小球性血尿的敏感度、特异度ROC曲线下面积为0.967(P<0.01)。二者曲线下面积比较,差异无统计学意义(u=0.03,P>0.05),二者诊断血尿来源的准确度相同。尿干化学分析中,尿蛋白阳性对于判断肾小球性血尿的敏感度为81.8%,特异度为65.2%。结论:联合UF-1000i流式尿有形成分分析仪、尿干化学分析仪及相差显微镜是鉴别血尿来源的最好策略。Objective:To evaluate the role of urine analysis by combining use of the UF-1000i flow cytometer,chemical strip test and the phase difference microscope in diganosing the origin of the hematuria.Methods:Thirty-three midstream urine samples from the patients with the glomerular hematuria and 23 midstream urine samples from the patients with the non-glomerular hematuria were collected.Each sample was examined in following aspects:counts of RBC,RBC-P70Fsc and RBC-Fsc-DW by UF-1000i flow cytometer;PRO by URISYS 2400 chemical strip analyzer;counts of RBC and proportion of abnormalities RBC by the phases difference microscope.Results:To diganosis of the origin of the hematuria,the sensitivity of the flow cytometer UF-1000i was 100%,and the specificity of it was 82.6%.The sensitivity of the phase difference microscope was 93.9%,and the specificity of it was 91.3%.The area under the ROC curve of the sensitivity and specificity was 0.966(P0.01),which was from the flow cytometer UF-1000i in diagnosing the glomerular hematuria.The area under the ROC curve of the sensitity and specificity was 0.967(P0.01),which was from the phases difference microscope in diagnosing the glomerular hematuria.There was no significant statistical difference (u=0.03,P0.05),by comparing the areas under the ROC curve.The accuracies were conformity by the tow methods in diagnosing the origin of the hematuria.The sensitivity and specificity of the chemical strip analyzer with PRO positive in diagnosing the glomerular hematuria were 81.8% and 65.2%.Conclusion:Combining use of the chemical strip analyzer,flow cytometer UF-1000i and the phase difference microscope is the best method in diagnosing the origin of the hematuria.
关 键 词:血尿 流式尿有形成分分析 相差显微镜 UF-1000i流式尿有形成分分析仪 尿干化学分析
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.229