基于瞬时无功功率理论的UPQC并联单元研究  被引量:3

Study on Shunt Unit of Unified Power Quality Conditioner Based on Instantaneous Reactive Power Theory

在线阅读下载全文

作  者:崔娟娟[1] 高沁翔[1] 周海玲[2] 刘智勇[1] 

机构地区:[1]北京交通大学电气工程学院,北京100044 [2]临沂师范学院物理系,山东临沂276000

出  处:《电测与仪表》2009年第11期24-27,80,共5页Electrical Measurement & Instrumentation

摘  要:随着配电系统中电能质量的日益恶化和用户对电能质量的要求越来越高,提高和改善电力系统的电能质量问题成为目前的研究重点。本文介绍了统一电能质量控制器的拓扑结构,同时给出了三相四线制系统并联有源滤波器的结构,重点研究了并联部分电流谐波的检测方法,即采用基于瞬时无功功率理论的谐波电流和无功检测方法,并通过实验针对电网中典型谐波源,三相整流桥所产生的谐波电流的补偿进行了仿真分析,从而表明所采用的检测方法的可行性和有效性。With the deterioration of power quality in distribution power system and customers' requirements on the quality and reliability of electrical power supply growing higher and higher, improving the power quality is becoming the focus problem in contemporary. This paper introduces topological structure of Unified Power Quality Controller, presents the active filter's structure of three-phase four-wire system, focuses on the detection of harmonic current in parallel parts, presents an approach of detecting harmonic and reactive power based on generalized instantaneous reactive Power theory, and gives the simulation analysis of three-phase rectifier bridge through experimental of the typical harmonic source in power grids. The results prove that the designed detecting method is flexible and effective.

关 键 词:瞬时无功功率理论 三相四线制系统 三相整流桥 无功和谐波 

分 类 号:TM76[电气工程—电力系统及自动化]

 