出  处:《太原科技》2009年第11期67-68,共2页Taiyuan Science and Technology

基  金:太原市2007年度平台建设计划项目

摘  要:采用"水解酸化+两段式接触氧化+混凝沉淀+过滤"工艺处理太原某制药公司中成药制药废水,设计水量600t/d,进水水质CODcr900mg/L,BOD5450mg/L,SS100mg/L。监测结果表明:处理后CODcr,BOD5与SS的去除率分别为90.2%,92.6%与82.3%,出水的各项指标符合GB8978—1996污水综合排放标准。By using the process of "hydrolysis acidification+two sections of contact oxidation+ coagulation precipitate + filtering" in dealing with waste water of making Chinese traditional patent medicine in a certain Taiyuan pharmaceutical company.The waste water quantity was 600 tons/day, CODcr, was900 mg/L, BOD5 was 450 mg/L, SS was 100 mg/L. The monitoring result showed that after the treatment, the removal percentage of CODcr, BOD5, SS are 90.2%, 92.6% and 82.3%. All indicators meet all the first degree of national integrated wastewater discharge standard(GB 8978--1996).

关 键 词:酸化水解 两段式接触氧化 混凝沉淀 制药废水 