1025 t/h直流锅炉水冷壁爆漏原因分析和改造  

1025 t/h Direct-current Boilers Water-cooling Wall Explodes to Leave Out Analysis of Causes and to Reform

在线阅读下载全文

作  者:刘业雄 

机构地区:[1]广东粤华发电有限责任公司,广东广州510731

出  处:《锅炉技术》2009年第6期64-67,共4页Boiler Technology

摘  要:通过对广东粤华发电有限责任公司1 025 t/h直流锅炉水冷壁的爆漏原因进行分析,提出了水冷壁改造的技术措施,介绍了在水冷壁改造过程中的注意事项。改造后,有效降低了锅炉水冷壁爆漏事故的发生,提高了锅炉运行的安全可靠性。直流锅炉水冷壁改造的经验对同类锅炉运行有参改价值。Cause go along has analysed the main body of a book by the fact that the wall exploding leaks to Guangdong China electric power generation limited liability company 1 025 t/h direct-current boiler hydroeooling , has brought forward the technology measure that water-cooling wall reforms , has introduced that in hydrocooling wall matters needing attention in reforming process. Reform the day afer tomorrow, have an effect to have reduced boiler hydrocooling wall occurrence exploding to leave out an accident, have improved working safe boiler reliability. Direct-current boiler hydrocooling wall make over experience has the ginseng changes value to the same kind boiler operation.

关 键 词:水冷壁爆漏 原因分析 改造措施 注意事项 

分 类 号:TK229.5[动力工程及工程热物理—动力机械及工程]

 