检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]自贡硬质合金有限责任公司,四川自贡643011
出 处:《湖南有色金属》2009年第6期57-61,共5页Hunan Nonferrous Metals
摘 要:文章采用iCAP6300型ICP光谱仪测定多种元素。以硝酸(1+1)溶解金属钴粉,用钴基体匹配,选择合适的背景校正方法和各元素最佳波长,用水平观测方式同时测定金属钴中的镁、铝、铜、锌、铁、铅、硅、锰、镍九种杂质元素含量。其检出限分别为/μg·g-1:0.34、0.17、0.21、0.18、0.19、0.24、0.16、0.14、0.29,相对标准偏差小于5%,标准加入回收率为92%~104%。该方法快速简便,准确度高,适用于生产分析。It uses iCAP 6300 ICP spectroscope to determine some elements. The metallic cobalt powders are dis- solved by nitric acid( 1 + 1), and matched with cobalt matrix. Selecting suitable background correction method and optimum wavelength of every elements, under this condition, the content of Mg, Al, Cu, Zn, Fe, Pb, Si, Mn, Ni in the metallic cobalt powders are determined by Axially Viewed. The detection limit(μg/g)of these elements above respectively are 0.17,0.21,0.18.0.19,0.24,0.16,0.14,0.29. The relative standard deviation is within 5%. Reclaimable rate is within 92% - 104%. This method is fast and convenient with high accuracy. It can be applied to production analysis.