检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:周晖[1] 江楚文[2] 李珩[1] 李世坚[1] 梁健群[1] 肖伟欢[3]
机构地区:[1]广东省医学科学院,广东省人民医院检验科,广州510080 [2]广东省人民医院省临床检验中心,广东广州510080 [3]广州医学院检验系,广州510182
出 处:《中国艾滋病性病》2009年第6期597-600,共4页Chinese Journal of Aids & STD
摘 要:目的分析综合医院艾滋病病毒(HIV)抗体筛查阳性样本的特征。方法分别用中山、梅里埃、丽珠三种酶联免疫吸附试验(ELISA)试剂和雅培硒标试剂筛查HIV抗体,筛查阳性样本用蛋白印迹法(WB)进行确认。分析确认阳性、不确定、阴性三组样本的特征。结果2004年1月至2009年3月共检测HIV抗体192636例,其中阳性样本349例。确认阳性组174例,流行率0.090%;2006-2008年显著高于2004-2005年(χ2=11.35,P=0.001),以21~50岁的青壮年男性居多。ELISA试剂均为阳性,S/CO值为(12.89±3.14);雅培试剂均为阳性;WB结果显示,91.38%HIV感染者呈现7条带以上。阳性-不确定组20例,ELISA试剂均为阳性,S/CO值为(4.90±3.40);雅培试剂7例阳性;呈现p24带者18例(90.00%),gp160带7例(35.00%),gp120、p17带各1例(各5.00%),其余带未呈现。1例随访后转阳性,3例随访转阴性。阳性-阴性组155例,心脏病人所占比例最高(26.45%)。ELISA试剂均为阳性,S/CO值为(2.63±2.54);雅培试剂15例阳性。结论HIV感染人数逐年增加;筛查阳性样本中存在一定的不确定、假阳性结果,应按规定程序进行确认。Objective To analyze the specimens with positive HIV antibody in screening tests from general hospitals. Methods From January 2004 to March 2009, three ELISA kits (Zhongshan, Biomerieux and Livzon) and a rapid test kit (Abbot Determine HIV-1/2 ) were used for screening HIV antibody. All repeatedly positive screening specimens were followed by WB assay. The three groups of specimens with positive, indeterminate and negative WB results were analyzed respectively. Results A total of 349 repeatedly positive specimens were obtained from 192 636 cases, with 174 positive, 20 indeterminate and 155 negative WB assay, HIV prevalence was 0. 090%, that in 2006 --2008 was signifieantly higher than in 2004--2005(Χ^2 =11.35, P =0.001). The higher prevalence was observed among males aged 21--50 years. All the 174 samples were positive by ELISA (S/CO 12.89±3.14) and Abbot kits, of which 159(91. 38%) specimens showed more than 7 bands by WB assay. Of 20 positive--indeterminate specimens. all were positive by ELISA(S/CO:4.90±3.40) and 7 were positive by Abbot kit. The bands which were more commonly present in WB indeterminate specimens were p24(90.00%,18/20) and gp160(35.00%, 7/20) one turned to WB positive and three turned to WB negative during the follow--up. Among 155 positive--negative cases, subjects with heart disease had the highest proportion of 26.45%. All were positive by EL/SA (S/CO:2.63 ±2.54) and 15 were positive by Abbot kit. Conclusions The number of HIV-infected cases is increasing year after year. All HIV antibody screening positive cases should be confirmed by WB assay because of the existence of inde- terminate and false positive results.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.229