检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]山西电力科学研究院,山西太原030001 [2]太原第二热电厂,山西太原030001
出 处:《山西电力》2009年第6期31-34,共4页Shanxi Electric Power
摘 要:以某电厂5号、6号凝汽50 MW机组通流部分改造为供热机组为例,主要论述了改造后投运在短期内发生3次叶片、叶轮断裂事故,经对断口宏观、微观以及机组改型前后运行实际状况、动叶结构及强度计算等分析,发现15级、16级叶片、叶轮在运行承受的动应力很大,且此区段的汽流扰动力极大,论证得出造成事故的主要原因是供热改造后15级、16级动强度不足所致。Taking No. 5 and No. 6 50 MW condensed steam as an example, three times breakages of the blade and bladed disc after the reconstruction of No. 5 and No. 6 unit flow passage changed to heat supply unit in 2000 and 2002 are discussed. According to the analysis of the fracture and practical operation situation before and after the reconstruction, the rotor blade structure and intensity calculation, the dynamic stress of 15 and 16 level blade and bladed disc need to be burdened is large, and its gas flow disturbing stress is huge, which can be concluded that the main cause of the accident is the shortage of 15 and 16 level dynamic stress after the heat supply reconstruction.
分 类 号:TP206.3[自动化与计算机技术—检测技术与自动化装置]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15