检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘爱国[1] 崔永华[1] 黄红彦[1] 葛新[1] 王春芳[1]
机构地区:[1]同济医科大学附属同济医院耳鼻咽喉科,武汉430030
出 处:《临床耳鼻咽喉科杂志》1998年第10期435-435,共1页Journal of Clinical Otorhinolaryngology
摘 要:利用耳动态分析仪ILO-92,对48例听力正常人(86耳)在4组不同原始刺激强度下(L1=L2=75dBSPL;L1=L2=65dBSPL;L1=L2=60dBSPL;L1=65dBSPL,L2=50dBSPL)进行畸变产物耳声发射(DPOAES)检查,结果发现平均DPOAEs图是双叶型轮廓:在1.5kHz和5kHz附近,2f1-f2DPOAEs存在两个高峰,在2.5~3kHz附近存在一个低谷,此图型结构无性别、耳别差异。DPOAEs反应的幅值随原始刺激强度增加而升高,平均幅值较原始刺激强度低55~65dBSPL。在4组不同原始刺激强度下,在1~6kHz范围内各个频率2f1-f2DPOAEs值存在显著性差异(P<0.05)。With ILO-92 Otodynamics Analyzer, distortion product otoacoustic emissions (DPOAEs)at the 2 f1-f2 frequency were recorded from 86 normally hearing ears in response to four groups of different primary levels (L1 = L2 = 75 dB SPL; L1 = L2 = 65 dB SPL; L1 = L2 = 60 dB SPL ;L1 = 65 dB SPL,L2 = 50 dB SPL). The average DPOAEs-gram demonstrated a bilobed contour with two peaks at approximately 1. 5 kHz and 5 kHz and a 'notch' between 2. 5 kHz and 3 kHz. Moreover,the contour of DPOAEs-gram had no obvious changes with sex,ear or primary stimulus levels differences. While the primary levels increased, the amplitude of DPOAEs gradua1ly increased,which was about 55~65 dB SPL below the primary levels. At each frequency from 1~6 kHz,statistical analysis showed that there existed significantly different DPOAEs level under four groups of different prirnary stimulus levels.
分 类 号:R339.16[医药卫生—人体生理学] R764.04[医药卫生—基础医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.229