R22和R417A应用于空气源热泵热水器的性能对比研究  被引量:3

The Research on comparison of performance between R22 and R417A Applied in The Air Source Heat Pump Water Heater

在线阅读下载全文

作  者:郑嘉耀[1] 金宁[1] 桂秋静[2] 

机构地区:[1]上海理工大学城市建设与环境工程学院,上海200093 [2]南京铁道职业技术学院,苏州215137

出  处:《制冷与空调(四川)》2009年第6期86-89,共4页Refrigeration and Air Conditioning

摘  要:在不同的环境温度下,对R417A在空气源热泵热水器应用中的性能特性和R22进行对比实验。结果表明:R417A可以直接替代R22在热泵热水器中使用。应用R417A替代R22,可以明显地降低排气温度和排气压力,有利于系统安全运行,提高压缩机的使用寿命。但是,在直接替代条件下,R417A制热性能系数(HCOP)比R22小。Comparison of characteristics between R417A and R22 in the air source heat pump water hearter (HPWH) were texted. The results indicate that: R417A can substitute for R22 in HPWH directly. The discharge temperature and the discharge pressure decreased obviously with using R417A, it is benefit for the safety operation of the system and raising the service life of compressor. However, with the lower consumption power and much lower heat capacity, the heat coefficient of performance (HCOP) of the HPWH using R417A is smaller than using R22.

关 键 词:热泵热水器 R417A 替代 HCOP 

分 类 号:TB64[一般工业技术—制冷工程] TM925.32[电气工程—电力电子与电力传动]

 