抽油机专用变压器2种调压节能技术的比较研究  被引量:1

Comparative Study of Two Voltage Regulation Energy-saving Technologies for Special Transformers of Pumping Units

在线阅读下载全文

作  者:辛绍杰[1] 王长忠[2] 钟力[2] 

机构地区:[1]上海电机学院机械学院,上海200245 [2]大庆职业学院机电系,大庆163255

出  处:《上海电机学院学报》2009年第4期259-262,共4页Journal of Shanghai Dianji University

基  金:国家火炬计划资助项目(042323002);科技部科技型企业技术创新基金资助项目(02C26212300543)

摘  要:介绍了抽油机专用变压器一次侧和二次侧调压节能装置及其实现,依据变压器负载与损耗的关系,以JNFDS 9型抽油机专用变压器为例,进行了2种调压方式变压器性能的比较研究。实践结果表明,二次侧调压技术较一次侧调压技术有更好的技术经济效果。Special transformers of pumping units based on high-voltage and low-voltage regulation energy saving devices are introduced in this paper. Based on the relationship between the load and the loss, and take the JNFDS 9-type special transformer of the pumping unit as an example, comparative study on the performance of two kinds of voltage regulation transformers is carried out. The results show that the low-voltage regulator technology, compared with the high-voltage regulator technology can obtain better technical and economic results.

关 键 词:抽油机专用变压器 一次侧调压技术 二次侧调压技术 性能 