生猪养殖场废水处理工程设计与运行调试  被引量:4

Design and operation of swine wastewater treatment plant

在线阅读下载全文

作  者:陈步东 王小佳[1,2] 卫培[3] 刘洋 吴根义[5] 

机构地区:[1]杭州楚天科技有限公司,浙江杭州31000 [2]同济大学污染控制及资源化国家重点实验室,上海200092 [3]同济大学政治与国际关系学院,上海200092 [4]美国哈希公司,上海200335 [5]湖南农业大学资源环境学院,湖南长沙410128

出  处:《广东农业科学》2010年第1期150-153,共4页Guangdong Agricultural Sciences

摘  要:采用厌氧—好氧—混凝沉淀工艺来处理高浓度养猪场废水。结果表明:经过该工艺处理后,原水COD由12 000 mg/L降为98 mg/L,SS浓度由4 500 mg/L降为20 mg/L,NH4+-N由1 160 mg/L降为59 mg/L,去除率分别为99.18%,95.56%和94.91%,达到《畜禽养殖业污染物排放标准》(GB 18596—2001)中规定的排放标准。该工艺具有工程造价低、易于管理等优点。The Anaerobic-aerobic-coagulation process was used for treating swine wastewater with high concentration. The results showed that COD concentration was decreased from 12 000 mg/L to 98 mg/L, SS and NH4+-N was decreased from 4 500 mg/L, 1 160 mg/L to 20 mg/L and 59mg/L, respectively. The removal rate were 99.18%, 95.56% and 94.91% respectively, which met the Discharge Standard of Pollutants For Livestock And Poultry Breeding (GB 18596-2001). This method had many advantages, such as the low costs of the building expenses and the easy controlling operation units.

关 键 词:养猪场污水 厌氧 好氧 化学混凝 

分 类 号:S216.4[农业科学—农业机械化工程]

 