钻机接零保护技术研究与实践  被引量:3

Rebuilding for TN Egis and Surge Suppresser of Oil Rig

在线阅读下载全文

作  者:王豫[1] 谭刚强[1] 孟军[1] 秦建忠[2] 李秉跃[1] 王鸿[3] 张卫东[2] 

机构地区:[1]川庆钻探工程有限公司装备处,成都610051 [2]川庆钻探工程有限公司长庆钻井总公司,西安710021 [3]西南油气田分公司装备处,成都610051

出  处:《石油矿场机械》2010年第1期25-31,共7页Oil Field Equipment

摘  要:220/380V供电系统有3种接地型式,钻机属中性点接地系统,应采用接零保护(TN)系统。对钻机进行接零保护整改,安装井场、值班房和生活区总等电位联结,以及将TN-C改造为TN-C-S或TN-S系统后,可提高自动切断供电措施的有效性和可靠性,解决用电设备外壳带电的问题;进行接地安全隐患整改和防雷接地安装,可消除钻机接地安全隐患。Three types of system grounding in power supply. The neutral earth protection system is commonly used in oil drilling rig and TN system is adopted. After improvement of neutral earth protection system, equipotential connection on rig site, dog house and well campsite, and the change TN-C into TN C S or TN S system, the effectiveness and reliability of auto breaking was increased and the problem of electrical casing with electricity could be solved. The use of the principle can eliminate the hidden trouble in rig.

关 键 词:石油钻机 接零保护 防雷接地 技术方案 

分 类 号:TE922[石油与天然气工程—石油机械设备]

 