SHPB装置应用于测量高温动态力学性能的研究  被引量:25

Application of SHPB Apparatus to the Measurement of High Temperature Dynamical Mechanical Behavior of Materials

在线阅读下载全文

作  者:夏开文[1] 程经毅[1] 胡时胜[1] 

机构地区:[1]中国科学技术大学力学与机械工程系

出  处:《实验力学》1998年第3期307-313,共7页Journal of Experimental Mechanics

基  金:国家高技术激光技术领域资助

摘  要:SHPB(分离式Hopkinson压杆)装置由于具有结构简单、操作方便等优点,为人们普遍采用;但作测量材料的动态高温力学性能方面还存在诸多不便之处。本文研究了附有恒温加热炉的SHPB装置,利用一维应力波传播理论和传热学原理,修正了温度梯度场对波形测量的影响,从而使SHPB装置用于高温动态力学测量更为准确可靠;并实际测量了30CrMnSiA钢从室温到高温(600℃)的动态(1.5~4.0×103s-1)应力应变曲线。Being simple in structure and easy to operate, SHPB apparatus is a common facility for measuring the dynamic mechanical behavior of materials. But for measurement of high temperature mechanical properties, attention should be paid to the temperature gradient existing in the input and output bars of the apparatus, which certainly has some efect on the measured waves. In this paper, based on the theory of one dimensional wave propagation and heat conduction, a data processing method for considering this unfavourable effect is suggested. By using the method, the dynamic mechanical properties of 30CrMnSiA at high temperature condition are measured more accurately.

关 键 词:SHPB装置 高温 动态力学性能 温度梯度场 应力波 

分 类 号:TB302.3[一般工业技术—材料科学与工程]

 