基于STATCOM的电弧炉负荷治理研究  被引量:3

STATCOM -Based Governace of Electric Arc Furnace Load

在线阅读下载全文

作  者:刘观起[1] 郑倩[1] 

机构地区:[1]华北电力大学电气与电子工程学院,河北保定071003

出  处:《电力科学与工程》2010年第2期18-21,共4页Electric Power Science and Engineering

摘  要:针对电弧炉负荷的电压波动、闪变与低功率因数等特性,分析了其工作原理。用PSCAD软件构造电弧炉模型、三相STATCOM及三单相STATCOM,并进行了仿真。分析了两种电路结构STATCOM对电弧炉负荷的治理效果。三单相STATCOM由于具有输出无功电流谐波含量低、响应速度快等优点而更加适合于电弧炉负荷的平衡化补偿。通过仿真验证了三单相STATCOM进行快速平衡化补偿的能力比较强。In this paper, according to the fuctuation and flicker, low power factor and other charateristics of electric arc furnace, the software PSCAD is used to structure the model of arc furnace and simulat it. The paper analized the principle of arc furnace, three-phase and single phase STATCOM, and separately construction three-phase and single phase STATCOM to control electric arc furnace. Due to the low harmonics in output reactive current and fast response characteristics, single phase STATCOM is suitable for balancing compensation of three phase unbalanced load. It was proved by the simulation results of the proposed compensation method that the single phase STATCOM possesses the ability to carry out fast balancing compensation.

关 键 词:STATCOM 电弧炉 平衡化补偿 

分 类 号:TM732[电气工程—电力系统及自动化]

 