水平管外降膜蒸发传热性能实验研究  被引量:5

Experimental research on heat transfer performance of falling film evaporation on horizontal tubes

在线阅读下载全文

作  者:齐鲁山[1] 马虎根[1] 李长生[1] 罗忠 

机构地区:[1]上海理工大学能源与动力工程学院,上海200093 [2]高克联管件(上海)有限公司,上海200131

出  处:《上海理工大学学报》2010年第1期27-30,共4页Journal of University of Shanghai For Science and Technology

摘  要:建立了降膜蒸发实验台,研究了在低压状态下水平管喷淋降膜蒸发的传热性能.实验蒸发管分别使用光管和某种型号强化管.实验测试了管子结构、喷淋流量以及在喷淋液中加入添加剂对换热的影响.结果表明,喷淋流量增大,管外换热系数和总传热系数都会有一定的增加,当增大到一定程度会出现换热效果变差的情况.强化管的总传热系数比普通光管高62%.本次实验使用的质量分数为4.15%的添加剂对于换热无强化效果.A falling film evaporator test-rig was designed and established to study the heat transfer performance of spray falling film evaporation on horizontal tubes at low pressure. Smooth tubes and some kinds of enhanced tubes were taken as test objects. The impacts of tube structure, spray flow, and additives in spray solution on the heat transfer performance were studied experimentally. By analyzing the experimental results it is shown that with the increase of flow rate of spray liquid, the evaporative heat transfer coefficient and the overall heat transfer coefficient have a certain degree of increase. However, when the flow increases to a certain extent, there may appear an instance at that the effects of heat transfer become worse. The heat transfer coefficient of enhanced tubes is higher by 62% than that of smooth tubes. In this experiment,4.15% mass fraction of the additive has no enhancing effect on falling film evaporation heat transfer.

关 键 词:降膜蒸发 喷淋 水平管 低压 

分 类 号:TK124[动力工程及工程热物理—工程热物理]

 