检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]辽东学院,辽宁丹东118003 [2]天津工业大学,天津300160
出 处:《纺织学报》2010年第3期123-127,共5页Journal of Textile Research
基 金:辽宁省科技厅科技攻关项目(2003220026);丹东市科技局科技攻关项目(06133)
摘 要:对AFIS与aQura 2种测试仪的测试稳定性进行了对比研究。将2次不同实验(每次实验包括12个方案)条件下所生产的生条分别用AFIS与aQura仪器进行检测,用统计学的方法对检测结果进行分析,得出了2种仪器共有测试参数的稳定测试次数的范围和均值。认为AFIS与aQura 2种仪器在检测带籽屑棉结含量和尺寸及棉结总数方面的稳定性差异相当明显,aQura的测试稳定性要远远高于AFIS;在检测棉结平均尺寸、5%长度、质量短绒率和根数短绒率指标方面,2种仪器的测试稳定性差异不大,测试稳定性均较高。This paper makes a comparative analysis on testing stability between AFIS and aQura.After testing card sliver produced by two different experiments(twelve plans in each experiment) with AFIS and aQura,the test results are analyzed with the theory of statistical analysis and the range and average of test times that can get a reliable test result of common test parameters of AFIS and aQura are calculated.The following conclusions are drawn that for the parameters of SCN number,SCN size and total neps number,the testing stability with aQura is much better than that with AFIS.For the parameters of nep mean size,5% length,short fiber content by weight and short fiber content by number,there is no evident difference in test stability between aQura and AFIS,and test stability of them are all very high.
关 键 词:PremieraQura AFIS 带籽屑棉结 棉结总数 5.0%长度 根数短绒率 质量短绒率 测试稳定性
分 类 号:TS103.62[轻工技术与工程—纺织工程]