发生炉煤气终冷增压方案的选择与效益性分析  被引量:2

The selection and benefit analysis on coal gas end cold and pressurized project

在线阅读下载全文

作  者:苑卫军[1] 秦利生[1] 李建胜[1] 

机构地区:[1]唐山科源环保技术装备有限公司,河北唐山063020

出  处:《能源工程》2009年第6期54-57,共4页Energy Engineering

摘  要:针对煤气饱和水对燃烧过程的影响程度与终冷增压的电力消耗,综合计算了五个终冷增压工艺方案的相关数据,并从经济合理性和环境影响程度出发,对其进行了系统的对比分析,指出经过初级冷却的煤气,其温度降至800-100℃后,不经过进一步终冷而直接增压输送的工艺,是最经济合理、环境效益最好的方案。According to the influence degree of saturated water on combustion process and the power consumption in the process of end cold and pressurized,the data of five end cold and pressurized processes were calculated and contrast analysis of these systems from the aspect of the economic rationality and environment was conducted.It pointed out that after the initial cooling,the gas temperature dropped to 80-100℃,and direct pressurization and transportation process without further end cold was the most economical and environmental process.

关 键 词:发生炉煤气 终冷增压 饱和水 电耗 煤气温度 经济效益 环境效益 

分 类 号:TK174[动力工程及工程热物理—热能工程]

 