ICP-MS测定镀锌板镀层中铅、镉、铬的含量  被引量:9

Determination of lead cadmium and chromium in galvanized plate coating by ICP-MS

在线阅读下载全文

作  者:李政军[1] 赵泉[1] 翟翠萍[1] 方永康[1] 李波平[1] 杨蓓[1] 沈文洁[1] 萧达辉[1] 郑建国[1] 

机构地区:[1]广东出入境检验检疫局,广州510623

出  处:《分析试验室》2010年第3期69-71,共3页Chinese Journal of Analysis Laboratory

基  金:国家质量监督检验检疫总局科研(2008IK053)项目资助

摘  要:利用ICP-MS测定镀锌板镀层中铅、镉、铬的含量。对ICP-MS测定条件进行了最佳化的选择,利用在线内标等技术,可降低基体干扰,直接检测元素的含量,方法的检出限为1.53~36.3μg/L,回收率为82.4%~94.5%。A method for the determination of Pb,Cd,Cr in galvanized plate coating have been developed by ICP-MS.Using on-line internal standard technology,the experimental conditions of ICP-MS were optimized.The matrix interference was reduced and sensitivity was improved.The detection limits and recoveries of the method are in the range of 1.53~36.3 μg/L and 82.4%~94.5% respectively.

关 键 词:电感耦合等离子质谱 镀锌板镀层    