检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]河北工业大学
出 处:《暖通空调》2010年第3期79-82,共4页Heating Ventilating & Air Conditioning
基 金:国家自然科学基金资助项目(编号:50906020);天津市科技支撑计划重点项目(编号:07ZCKFSF00400)
摘 要:实验研究了原土(粉细砂)和中粗砂回填条件下双U形地埋管换热器的传热性能,获得了换热量随管内流体平均温度的实测变化曲线。结果表明,换热量与流体平均温度之间呈线性变化规律,在地埋换热器工作温度范围内,中粗砂回填时的换热量比粉细砂回填时高约10%(取热工况)和6%(排热工况)。建议在选择回填材料时,应在考虑其对地埋管换热器传热特性影响的基础上,进一步考虑其经济性。Makes an experiment on the heat transfer performance of double U-shaped geothermal heat exchangers(GHE)under the backfill materials of fine sand and medium-coarse sand,and obtains the variation curve of the underground heat transfer rate with the average in-tube fluid temperature.Experimental results show that there is a linear relationship between the underground heat transfer rate and the average fluid temperature.Within the normal operation temperature range of GHE,the underground heat transfer rate for fine sand is 10% for heat injection mode and 6% for heat extraction mode higher than that of medium-coarse sand.Suggests that selection of the backfill materials should base on both its influences on the heat transfer performance of GHE and its economic efficiency.
分 类 号:TU831.4[建筑科学—供热、供燃气、通风及空调工程]