检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:罗新[1] 张强[1] 刘鸿[1] 龙冲生[1] 李卫军[1]
机构地区:[1]中国核动力研究设计院核燃料及材料国家级重点实验室,四川成都610041
出 处:《原子能科学技术》2010年第2期193-196,共4页Atomic Energy Science and Technology
基 金:核燃料及材料国家级重点实验室基金资助项目(QPA424UMATIBOYY03C)
摘 要:研究采用图像分析技术测量包覆颗粒的疏松碳涂层密度,包括图像采集硬件和分析软件。通过对颗粒的实际测量和扫描电镜观察,对测量方法的可靠性进行了评价。在分析测量过程中不确定度主要来源的基础上,对不确定度分量及合成不确定度进行了计算。结果表明,本方法具有灵活方便、速度快、维护简单等特点,可直接用于包覆颗粒涂层性能评价。The image analysis technique was developed to measure the density of porous pyrocarbon on coated particles (CP), which consisted of image collecting hardware and analysis software. The reliability of the technique was assessed based on particle meas- urement and SEM (scanning electron microscopy) observation. The uncertainty compo- nents and combined uncertainty were evaluated by analyzing the main sources of uncer- tainty in measurement. The technique is suitable for the capability evaluation of CP coatings due to its convenience, rapidity, and easy maintenance.
分 类 号:TL352.2[核科学技术—核技术及应用]