铅试金富集-塞曼石墨炉原子吸收光谱法测定矿石样品中铂钯铑铱  被引量:34

Determination of platinum,palladium,rhodium and iridium in mineral samples by Zeeman graphite furnace atomic absorption spectrometry after the preconcentration with lead fire assaying

在线阅读下载全文

作  者:倪文山[1,2] 孟亚兰[1,2] 姚明星[1,2] 张萍[1,2] 范攀峰[1,2] 李贤珍[1,2] 

机构地区:[1]中国地质科学院郑州矿产综合利用研究所,河南郑州450006 [2]国家非金属矿资源综合利用工程技术研究中心,河南郑州450006

出  处:《冶金分析》2010年第3期23-26,共4页Metallurgical Analysis

摘  要:建立了铅试金富集-塞曼石墨炉原子吸收光谱法测定矿石样品中铂、钯、铑、铱的新方法。运用传统的铅试金方法熔融分解矿石样品,且采用留铅灰吹的方法使样品中铂、钯、铑、铱富集在约3mg的铅合粒中。先用HNO3溶解铅合粒,再加入HCl以形成王水溶解,使铂、钯、铑、铱完全进入溶液,然后采用塞曼石墨炉原子吸收光谱法于选定的仪器参数条件下测定。本方法运用二次方程最小二乘法拟合校准曲线,曲线拟合良好。铂、钯、铑、铱的校准曲线拟合系数分别为0.9999、0.9999、0.9992、0.9994;特征浓度分别为1.8542ng/mL、1.5435ng/mL、0.4883ng/mL、0.4811ng/mL;相对标准偏差为:Pt 1.5%~4.5%、Pd 1.1%~2.9%、Rh 3.4%~6.3%、Ir 2.9%~5.8%。运用本方法测定标准物质中铂、钯、铑、铱含量,测定结果与认定值相吻合。A novel method for determining platinum palladium, rhodium and irdium in mineral sample was established using Zeeman graphite furnace atomic absorption spectrometry. Mineral sample was melten using traditional lead fire assaying, and platinum, palladium, rhodium and irdium was accumulated in 3 mg of lead by cupellation. This alloy was dissolved in HNO3, and then HCl was added to form aqua regia solution to make sure that platinum, palladium, rhodium and irdium were fully dissolved in this solution. The concentration of the above four elements was detected at the selected instrumental parameters using Zeeman graphite furnace atomic absorption spectrometry. A calibration curve was created based on linear least squares fitting technique with a satisfactory curve fitting effect. The standard correlation coefficients are 0. 999 9, 0. 999 9, 0. 999 2 and 0. 999 4,and the characteristic concentration is 1. 854 2 ng/mL, 1. 543 5 ng/mL, 0. 488 3 ng/mL, and 0. 481 1 ng/mL for platinum, palladium, rhodium and irdium, respectively. The relative standard deviations (n = 4) are 1.5%- 4.5% (Pt), 1.1%-2.9% (Pd), 3.4%-6.3% (Rh), 2.9%-5.8% (Ir). The concentration of platinum, palladium, rhodium and irdium of standards material detected by this method is consistent with the certified value.

关 键 词:铅试金     塞曼石墨炉原子吸收光谱法 

分 类 号:TF041[冶金工程—冶金物理化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象