板式低温空气预热器出口端隔板开裂失效分析及维修  被引量:5

Failure Analysis and Repair for Baffler at Outlet End Cracking in Low Temperature Plate Air Preheater

在线阅读下载全文

作  者:张绍良 郭志军[2] 

机构地区:[1]中国海油惠州炼油分公司,广东惠州516086 [2]甘肃蓝科石化高新装备股份有限公司,甘肃兰州730070

出  处:《石油化工设备》2010年第2期88-92,共5页Petro-Chemical Equipment

摘  要:对制氢转化炉用低温空气预热器在运行中出现内漏的原因进行了检查、分析,认为内漏是在装置开、停过程中,在介质露点温度下,烟气和空气冷凝液中的Cl-导致部分烟气出口端隔板与端板角焊缝发生了应力腐蚀开裂所致。据此提出了维修措施、结构改进及操作建议。A test and inspection was made for the inner leakage in heater in hydrogen unit reformer and the analysis was made as well. a low temperature plate air After inspection, the leakage was found at flue gas outlet end and header fillet weld crack casused by stress corrosion of C1- ex- isting in flue gas and atmosphere condensate at media dew point temperature during staring-up and stopping. The repair measures, structure develpoment and operation propsal are proposed.

关 键 词:制氢装置 板式空气预热器 露点腐蚀 应力腐蚀 失效分析 维修 

分 类 号:TQ051.501[化学工程] TQ050.1

 