检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]浙江理工大学流体输送技术实验室,杭州310018 [2]浙江大学流体传动及控制国家重点实验室,杭州310027 [3]浙江天德泵业有限公司,苍南325800
出 处:《农业机械学报》2010年第3期96-99,共4页Transactions of the Chinese Society for Agricultural Machinery
基 金:国家自然科学基金资助项目(20706049;50879080);国家重点基础研究发展计划资助项目(2009CB724300);浙江省重大科技攻关计划资助项目(2008C01024-1)
摘 要:采用闭式流体输送试验台,对具有前置诱导轮的高速离心泵进行了汽蚀特性试验研究,比较分析了无诱导轮、单个及串联诱导轮3种工况下诱导轮对离心泵性能及汽蚀性能的影响。发现前置单个或串联诱导轮对离心泵的性能影响并不显著,单个诱导轮的离心泵性能相对于无诱导轮的离心泵性能稍有下降,具有串联诱导轮的离心泵扬程和效率与无诱导轮离心泵相比稍有增加;但采用串联诱导轮可有效提高离心泵的汽蚀性能。Experimental research on suction performance was carried out on high-speed centrifugal pump with inducer by using closed test.The effect on the characteristic and suction performance of the centrifugal pump was analyzed with no inducer,one and two-phase inducers.It was found that one or two-phase inducers had little influence on the characteristic performance of a centrifugal pump.Compared with no inducer,the head and efficiency decreased slightly by using one inducer,and they slightly increased by using a two-phase inducer.But suction performance of centrifugal pump was improved by using a two-phase inducer.