Measurement and control for a repetitive nanosecond-pulse breakdown experiment in polymer films  被引量:1

Measurement and control for a repetitive nanosecond-pulse breakdown experiment in polymer films

在线阅读下载全文

作  者:邵涛 章程 龙凯华 王珏 张东东 严萍 

机构地区:[1]Institute of Electrical Engineering,Chinese Academy of Sciences

出  处:《Chinese Physics B》2010年第4期168-172,共5页中国物理B(英文版)

基  金:Project supported by the National Natural Science Foundation of China (Grant Nos. 50707032 and 50437020);the Knowledge Innovation Program of the Chinese Academy of Sciences (Grant No. KGCX2-YW-339);the State Key Laboratory of Controland Simulation of Power System and Generation Equipment in Tsinghua University (Grant No. SKLD09KZ05)

摘  要:In order to perform data acquisition and avoid unwanted over-current damage to the power supply, a convenient and real-time method of experimentally investigating repetitive nanosecond-pulse breakdown in polymer dielectric samples is presented. The measurement-acquisition and control system not only records breakdown voltage and current, and time-to-breakdown duration, but also provides a real-time power-off protection for the power supply. Furthermore, the number of applied pulses can be calculated by the product of the time-to-breakdown duration and repetition rate. When the measured time-to-breakdown duration error is taken into account, the repetition rate of applied nanosecond-pulses should be below 40kHz. In addition, some experimental data on repetitive nanosecond-pulse breakdown of polymer films are presented and discussed.In order to perform data acquisition and avoid unwanted over-current damage to the power supply, a convenient and real-time method of experimentally investigating repetitive nanosecond-pulse breakdown in polymer dielectric samples is presented. The measurement-acquisition and control system not only records breakdown voltage and current, and time-to-breakdown duration, but also provides a real-time power-off protection for the power supply. Furthermore, the number of applied pulses can be calculated by the product of the time-to-breakdown duration and repetition rate. When the measured time-to-breakdown duration error is taken into account, the repetition rate of applied nanosecond-pulses should be below 40kHz. In addition, some experimental data on repetitive nanosecond-pulse breakdown of polymer films are presented and discussed.

关 键 词:nanosecond-pulse breakdown repetitive nanosecond pulses polymer film time-to-breakdown duration 

分 类 号:O484.5[理学—固体物理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象