摘  要:A method based on circuit model is used to tune the first home-made 9-cell TESLA type superconducting niobium cavity at Peking University. After tuning, a flat field profile with a final π-mode frequency within 3 kHz of target frequency is achieved. The field flatness is measured by a bead-pull method, and the relative electric field is calculated from the frequency shift perturbed by the bead stepping along the axis of the cavity.A method based on circuit model is used to tune the first home-made 9-cell TESLA type superconducting niobium cavity at Peking University. After tuning, a flat field profile with a final π-mode frequency within 3 kHz of target frequency is achieved. The field flatness is measured by a bead-pull method, and the relative electric field is calculated from the frequency shift perturbed by the bead stepping along the axis of the cavity.