检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]湖南省娄底市中心医院骨科,湖南娄底417000
出 处:《生物骨科材料与临床研究》2010年第2期50-52,共3页Orthopaedic Biomechanics Materials and Clinical Study
摘 要:目的探讨利用跟骨解剖型钢板内固定治疗跟骨骨折的疗效。方法跟骨关节内粉碎性骨折23例,采用跟骨外侧可延伸的L形切口入路,切开撬拨复位解剖钢板内固定。结果所有患者均获得6~32个月的随访,根据Maryland足部评分系统:优10例,良7例,可6例,优良率73.9%。末次随访X线片上的跟骨形态学指标(Bohler角)较术前均有明显改善,差异有统计学意义(<0.05)结论跟骨解剖型钢板内固定对跟骨骨折治疗疗效满意。Objective To investigate the effect of internal fixation with anatomic plate on frature of calcaneal. Method 23 patients of severely displaced intra-articular frature were enrolled.The treatment consist of open reduction and internal fixation with anatomic plate through a extensile "L"shape lateral approach. Result All patirents were followed up for 6-32 months,According to the Maryland Foot Scores,the result were excellent in 10 patirents,good in 7,and fair in 6,the excellent and good rate was 73.9%.The indexes of calcaneal morphology at the last follow-up had a significant improvement compared with the preoperative ones (P〈0.05). Conclusion The effect of the calcaneal frature with anatomic plate to internal fixation is satisfactory.
正在载入数据...